Description
P-Net before 1.0.4 sets the alarm receiver state to waiting for confirmation before the data of a received alarm notification is parsed. If the parsing fails the state is not restored, and later alarm notifications of the same priority are discarded without acknowledge until the Application Relationship is released. The Application Relationship and the cyclic data exchange keep working. The attacker must be able to send an alarm notification in the context of an established Application Relationship and requires ADJACENT network access.
Analysis and contextual insights are available on OpenCVE Cloud.
Remediation
Vendor Solution
Upgrade to P-Net 1.0.4 or later.
Tracking
Sign in to view the affected projects.
Advisories
No advisories yet.
References
History
Fri, 13 Nov 2026 13:30:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | P-Net before 1.0.4 sets the alarm receiver state to waiting for confirmation before the data of a received alarm notification is parsed. If the parsing fails the state is not restored, and later alarm notifications of the same priority are discarded without acknowledge until the Application Relationship is released. The Application Relationship and the cyclic data exchange keep working. The attacker must be able to send an alarm notification in the context of an established Application Relationship and requires ADJACENT network access. | |
| Title | Alarm receiver stops delivering alarms after a malformed alarm notification | |
| Weaknesses | CWE-754 | |