| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Authentication credentials leakage vulnerability in Hitachi Ops Center Common Services within Hitachi Ops Center OVA.
This issue affects Hitachi Ops Center Common Services: from 10.9.3-00 before 11.0.3-00; Hitachi Ops Center OVA: from 10.9.3-00 before 11.0.2-01. |
| Adtec Digital SignEdje Digital Signage Player v2.08.28 contains multiple hardcoded default credentials that allow unauthenticated remote access to web, telnet, and SSH interfaces. Attackers can exploit these credentials to gain root-level access and execute system commands across multiple Adtec Digital product versions. |
| A vulnerability classified as problematic was found in SAFECAM X300 up to 20250611. This vulnerability affects unknown code of the component FTP Service. The manipulation leads to use of default credentials. Access to the local network is required for this attack to succeed. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| By default, the password for the Access Manager's web interface, is set to 'admin'. In the tested version changing the password was not enforced. |
| Longse NVR (Network Video Recorder) model NVR3608PGE2W, as well as products based on this device, create a WiFi network with a default password.
A user is neither advised to change it during the installation process, nor such a need is described in the manual. As the cameras from the same kit connect automatically, it is very probable for the default password to be left unchanged. |
| A vulnerability classified as critical has been found in Sony SNC-M1, SNC-M3, SNC-RZ25N, SNC-RZ30N, SNC-DS10, SNC-CS3N and SNC-RX570N up to 1.30. This affects an unknown part of the component Administrative Interface. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. It is recommended to change the configuration settings. The vendor was contacted early about this issue. They confirmed the existence but pointed out that they "have published the 'Hardening Guide' on the Web from July 2018 to January 2025 and have thoroughly informed customers of the recommendation to change their initial passwords". |
| iMonitor EAM 9.6394 ships with default administrative credentials that are also displayed within the management client’s connection dialog. If the administrator does not change these defaults, a remote attacker can authenticate to the EAM server and gain full control over monitored agents and data. This enables reading highly sensitive telemetry (including keylogger output) and issuing arbitrary actions to all connected clients. |
| NetBird VPN when installed using vendor's provided script failed to remove or change default password of an admin account created by ZITADEL.
This issue affects instances installed using vendor's provided script. This issue may affect instances created with Docker if the default password was not changed nor the user was removed.
This issue has been fixed in version 0.57.0 |
| If misconfigured, alpitronic Hypercharger EV charging devices can expose a web interface
protected by authentication. If the default credentials are not changed,
an attacker can use public knowledge to access the device as an
administrator. |
| Use of Default Cryptographic Key in the hardware for some Intel(R) Pentium(R) Processor Silver Series, Intel(R) Celeron(R) Processor J Series, Intel(R) Celeron(R) Processor N Series may allow an escalation of privilege. Hardware reverse engineer adversary with a privileged user combined with a high complexity attack may enable escalation of privilege. This result may potentially occur via physical access when attack requirements are present with special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (high), integrity (none) and availability (none) of the vulnerable system, resulting in subsequent system confidentiality (high), integrity (high) and availability (none) impacts. |
| Ilevia EVE X1 Server firmware versions ≤ 4.7.18.0.eden contain a use of default credentials vulnerability that allows an unauthenticated attacker to obtain remote access. Ilevia has declined to service this vulnerability, and recommends that customers not expose port 8080 to the internet. |
| Use of Default Credentials, Hard-coded Credentials vulnerability in C2SGlobalSettings.dll in
Milner ImageDirector Capture on Windows allows decryption of document archive files using credentials decrypted with hard-coded application encryption key.
This issue affects ImageDirector Capture: from 7.0.9.0 before 7.6.3.25808. |
| Multiple services of the DUT as well as different scopes of the same service reuse the same credentials. |
| PTZOptics and possibly other ValueHD-based pan-tilt-zoom cameras use default, shared credentials for the administrative web interface. |
| Default credential in install package in ABB ASPECT; NEXUS Series; MATRIX Series version 3.07 allows attacker to login to product instances wrongly configured. |
| Airship AI Acropolis includes a default administrative account that uses the same credentials on every installation. Instances of Airship AI that do not change this account password are vulnerable to a remote attacker logging in and gaining the privileges of this account. Fixed in 10.2.35, 11.0.21, and 11.1.9. |
| The Thermo Fisher Torrent Suite Django application 5.18.1 has weak default credentials, which are stored as fixtures for the Django ORM API. The ionadmin user account can be used to authenticate to default deployments with the password ionadmin. The user guide recommends changing default credentials; however, a password change policy for default administrative accounts is not enforced. Many deployments may retain default credentials, in which case an attacker is likely to be able to successfully authenticate with administrative privileges. |
| A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The "intermediate installation" system state of the affected application uses default credential with admin privileges. An attacker could use the credentials to gain complete control of the affected device. |
| Default credentials on the Web Interface of Evolution Controller 2.x allows anyone to log in to the server directly to perform administrative functions. Upon installation or upon first login, the application does not ask the user to change the password. There is no warning or prompt to ask the user to change the default password. |
| A security issue was discovered in the Kubernetes Image Builder versions <= v0.1.37 where default credentials are enabled during the image build process. Virtual machine images built using the Proxmox provider do not disable these default credentials, and nodes using the resulting images may be accessible via these default credentials. The credentials can be used to gain root access. Kubernetes clusters are only affected if their nodes use VM images created via the Image Builder project with its Proxmox provider. |