| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Multiple hardcoded credentials in Xsuite 2.x. |
| CloudForms Management Engine before 5.8 includes a default SSL/TLS certificate. |
| An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application uses a hard-coded username with no password allowing an attacker into the system without authentication. |
| An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected |
| Hard-coded FTP credentials (r:r) are included in the Foscam C1 running firmware 1.9.1.12. Knowledge of these credentials would allow remote access to any cameras found on the internet that do not have port 50021 blocked by an intermediate device. |
| Huawei OceanStor 5600 V3 V300R003C00 has a hardcoded SSH key vulnerability; the hardcoded keys are used to encrypt communication data and authenticate different nodes of the devices. An attacker may obtain the hardcoded keys and log in to such a device through SSH. |
| IBM dashDB Local uses hard-coded credentials that could allow a remote attacker to gain access to the Docker container or database. |
| Axesstel MU553S MU55XS-V1.14 devices have a default password of admin for the admin account. |
| Backup archives were found to be encrypted with a static password across different installations, which suggest the same password may be used in all virtual appliance instances of Trend Micro Deep Discovery Director 1.1. |
| D-Link DIR-615 before v20.12PTb04 has a second admin account with a 0x1 BACKDOOR value, which might allow remote attackers to obtain access via a TELNET connection. |
| D-Link DIR-850L REV. B (with firmware through FW208WWb02) devices have a hardcoded password of wrgac25_dlink.2013gui_dir850l for the Alphanetworks account upon device reset, which allows remote attackers to obtain root access via a TELNET session. |
| D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices use the same hardcoded /etc/stunnel.key private key across different customers' installations, which allows remote attackers to defeat the HTTPS cryptographic protection mechanisms by leveraging knowledge of this key from another installation. |
| D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices have 0644 /var/etc/shadow (aka the /etc/shadow symlink target) permissions. |
| D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices have 0666 /var/run/hostapd* permissions. |
| In some circumstances, an F5 BIG-IP version 12.0.0 to 12.1.2 and 13.0.0 Azure cloud instance may contain a default administrative password which could be used to remotely log into the BIG-IP system. The impacted administrative account is the Azure instance administrative user that was created at deployment. The root and admin accounts are not vulnerable. An attacker may be able to remotely access the BIG-IP host via SSH. |
| The WePresent WiPG-1500 device with firmware 1.0.3.7 has a manufacturer account that has a hardcoded username / password. Once the device is set to DEBUG mode, an attacker can connect to the device using the telnet protocol and log into the device with the 'abarco' hardcoded manufacturer account. This account is not documented, nor is the DEBUG feature or the use of telnetd on port tcp/5885. |
| A Use of Hard-Coded Cryptographic Key issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External Transmitters, Telepole II, and MESH Repeater (Telemetry Enabled Devices). An unchangeable, factory-set key is included in the 900 MHz transmitter firmware. |
| The Epson "EasyMP" software is designed to remotely stream a users computer to supporting projectors.These devices are authenticated using a unique 4-digit code, displayed on-screen - ensuring only those who can view it are streaming.In addition to the password, each projector has a hardcoded "backdoor" code (2270), which authenticates to all devices. |
| A hard-coded password of tecn0visi0n for the dlxuser account in TecnoVISION DLX Spot Player4 (all known versions) allows remote attackers to log in via SSH and escalate privileges to root access with the same credentials. |
| The SMI-S service in Dell Storage Manager versions earlier than 16.3.20 (aka 2016 R3.20) is protected using a hard-coded password. A remote user with the knowledge of the password might potentially disable the SMI-S service via HTTP requests, affecting storage management and monitoring functionality via the SMI-S interface. This issue, aka DSM-30415, only affects a Windows installation of the Data Collector (not applicable to the virtual appliance). |