| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Insufficient encryption vulnerability in the mobile application (com.transsion.aivoiceassistant) may lead to the risk of sensitive information leakage. |
| ToolHive is a utility designed to simplify the deployment and management of Model Context Protocol (MCP) servers. Due to the ordering of code used to start an MCP server container, versions of ToolHive prior to 0.0.33 inadvertently store secrets in the run config files which are used to restart stopped containers. This means that an attacker who has access to the home folder of the user who starts the MCP server can read secrets without needing access to the secrets store itself. This only applies to secrets which were used in containers whose run configs exist at a point in time - other secrets remaining inaccessible. ToolHive 0.0.33 fixes the issue. Some workarounds are available. Stop and delete any running MCP servers, or manually remove any runconfigs from `$HOME/Library/Application Support/toolhive/runconfigs/` (macOS) or `$HOME/.state/toolhive/runconfigs/` (Linux). |
| An issue in the Sensor Settings of AVTECH Room Alert 4E v4.4.0 allows attackers to gain access to SMTP credentials in plaintext via a crafted AJAX request. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. |
| An issue in the SMTP Email Settings of AVTECH Room Alert 4E v4.4.0 allows attackers to gain access to credentials in plaintext via a passback attack. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. |
| SAP GUI for Windows may allow a highly privileged user on the affected client PC to locally access sensitive information stored in process memory during runtime.This vulnerability has a high impact on confidentiality, with no impact on integrity and availability. |
| The data stored in Be-Tech Mifare Classic card is stored in cleartext. An attacker having access to a Be-Tech hotel guest Mifare Classic card can create a master key card that unlocks all the locks in the building.
This issue affects all Be-Tech Mifare Classic card systems. To fix the vulnerability, it is necessary to replace the software, encoder, cards, and PCBs in the locks. |
| YugabyteDB diagnostic information was transmitted over HTTP, which could expose sensitive data during transmission |
| A flaw was found in Ansible Automation Platform (AAP) where the Gateway API returns the client secret for certain GitHub Enterprise authenticators in clear text. This vulnerability affects administrators or auditors accessing authenticator configurations. While access is limited to privileged users, the clear text exposure of sensitive credentials increases the risk of accidental leaks or misuse. |
| An issue was discovered in Teledyne FLIR M300 2.00-19. User account passwords are encrypted locally, and can be decrypted to cleartext passwords using the utility umSetup. This utility requires root permissions to execute. |
| An issue was discovered in the COROS application through 3.8.12 for Android. Bluetooth pairing and bonding is neither initiated nor enforced by the application itself. Also, the watch does not enforce pairing and bonding. As a result, any data transmitted via BLE remains unencrypted, allowing attackers within Bluetooth range to eavesdrop on the communication. Furthermore, even if a user manually initiates pairing and bonding in the Android settings, the application continues to transmit data without requiring the watch to be bonded. This fallback behavior enables attackers to exploit the communication, for example, by conducting an active machine-in-the-middle attack. |
| The MOD3 command traffic between the monitoring application and the
inverter is transmitted in plaintext without encryption or obfuscation.
This vulnerability may allow an attacker with access to a local network
to intercept, manipulate, replay, or forge critical data, including
read/write operations for voltage, current, and power configuration,
operational status, alarms, telemetry, system reset, or inverter control
commands, potentially disrupting power generation or reconfiguring
inverter settings. |
| Kaseya Rapid Fire Tools Network Detective 2.0.16.0 has Unencrypted Credentials (for privileged access) stored in the collector.txt configuration file. |
| phpgt/Dom provides access to modern DOM APIs. Versions of phpgt/Dom prior to 4.1.8 expose the GITHUB_TOKEN in the Dom workflow run artifact. The ci.yml workflow file uses actions/upload-artifact@v4 to upload the build artifact. This artifact is a zip of the current directory, which includes the automatically generated .git/config file containing the run's GITHUB_TOKEN. Seeing as the artifact can be downloaded prior to the end of the workflow, there is a few seconds where an attacker can extract the token from the artifact and use it with the GitHub API to push malicious code or rewrite release commits in your repository. Any downstream user of the repository may be affected, but the token should only be valid for the duration of the workflow run, limiting the time during which exploitation could occur. Version 4.1.8 fixes the issue. |
| A local, low-privileged attacker can learn the password of the connected controller in PLC Designer V4 due to an incorrect implementation that results in the password being displayed in plain text under special conditions. |
| A vulnerability classified as problematic was found in Netis WF-2404 1.1.124EN. Affected by this vulnerability is an unknown functionality of the component BusyBox Shell. The manipulation leads to cleartext storage of sensitive information. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| The MIB3 unit stores the synchronized phone contact book in clear-text, allowing an attacker with either code execution privilege on the system or physical access to the system to obtain vehicle owner's contact data.
The vulnerability was originally discovered in Skoda Superb III car with MIB3 infotainment unit OEM part number 3V0035820. The list of affected MIB3 OEM part numbers is provided in the referenced resources. |
| CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that exposes test
credentials in the firmware binary |
| IPMI credentials may be captured in XCC audit log entries when the account username length is 16 characters. |
| Valmet DNA user passwords in plain text. This practice poses a security risk as attackers who gain access to local project data can read the passwords. |
| On Arista CloudVision Appliance (CVA) affected releases running on appliances that support hardware disk encryption (DCA-350E-CV only), the disk encryption might not be successfully performed. This results in the disks remaining unsecured and data on them |