Search Results (24362 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-53367 2026-04-15 N/A
DjVuLibre is a GPL implementation of DjVu, a web-centric format for distributing documents and images. Prior to version 3.5.29, the MMRDecoder::scanruns method is affected by an OOB-write vulnerability, because it does not check that the xr pointer stays within the bounds of the allocated buffer. This can lead to writes beyond the allocated memory, resulting in a heap corruption condition. An out-of-bounds read with pr is also possible for the same reason. This issue has been patched in version 3.5.29.
CVE-2024-31162 1 Asus 1 Download Master 2026-04-15 7.2 High
The specific function parameter of ASUS Download Master does not properly filter user input. An unauthenticated remote attacker with administrative privileges can exploit this vulnerability to execute arbitrary system commands on the device.
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2025-5106 2026-04-15 7.3 High
A vulnerability was found in Fujian Kelixun 1.0. It has been classified as critical. This affects an unknown part of the file /app/fax/fax_view.php of the component Filename Handler. The manipulation of the argument fax_file leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-31408 2026-04-15 N/A
OS command injection vulnerability exists in AIPHONE IX SYSTEM and IXG SYSTEM. A network-adjacent authenticated attacker may execute an arbitrary OS command with root privileges by sending a specially crafted request.
CVE-2024-33434 1 Tiagorlampert 1 Chaos 2026-04-15 9.8 Critical
An issue in tiagorlampert CHAOS v5.0.1 before 1b451cf62582295b7225caf5a7b506f0bad56f6b and 24c9e109b5be34df7b2bce8368eae669c481ed5e allows a remote attacker to execute arbitrary code via the unsafe concatenation of the `filename` argument into the `buildStr` string without any sanitization or filtering.
CVE-2024-3346 1 Byzoro 1 Smart S80 2026-04-15 6.3 Medium
A vulnerability was found in Byzoro Smart S80 up to 20240328. It has been declared as critical. This vulnerability affects unknown code of the file /log/webmailattach.php. The manipulation of the argument mail_file_path leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-259450 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-36060 1 Engeniustech 1 Enstation5-ac Firmware 2026-04-15 8.8 High
EnGenius EnStation5-AC A8J-ENS500AC 1.0.0 devices allow blind OS command injection via shell metacharacters in the Ping and Speed Test parameters.
CVE-2024-36103 2026-04-15 6.8 Medium
OS command injection vulnerability in WRC-X5400GS-B v1.0.10 and earlier, and WRC-X5400GSA-B v1.0.10 and earlier allows a network-adjacent attacker with an administrative privilege to execute arbitrary OS commands by sending a specially crafted request to the product.
CVE-2024-3721 2026-04-15 6.3 Medium
A vulnerability was found in TBK DVR-4104 and DVR-4216 up to 20240412 and classified as critical. This issue affects some unknown processing of the file /device.rsp?opt=sys&cmd=___S_O_S_T_R_E_A_MAX___. The manipulation of the argument mdb/mdc leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260573 was assigned to this vulnerability.
CVE-2025-48518 1 Amd 9 Radeon Pro V710, Radeon Pro W7000 Series, Radeon Rx 7000 Series and 6 more 2026-04-15 N/A
Improper input validation in AMD Graphics Driver could allow a local attacker to write out of bounds, potentially resulting in loss of integrity or denial of service.
CVE-2025-48499 1 Fujifilm 8 Apeos 2150, Apeos 2350, Docuprint M115 W and 5 more 2026-04-15 5.3 Medium
Out-of-bounds write vulnerability exists in FUJIFILM Business Innovation MFPs. A specially crafted IPP (Internet Printing Protocol) or LPD (Line Printer Daemon) packet may cause a denial-of-service (DoS) condition on an affected MFP. Resetting the MFP is required to recover from the denial-of-service (DoS) condition.
CVE-2025-48501 2026-04-15 N/A
An OS command injection issue exists in Nimesa Backup and Recovery v2.3 and v2.4. If this vulnerability is exploited, an arbitrary OS commands may be executed on the server where the product is running.
CVE-2024-38665 2026-04-15 8.4 High
Out-of-bounds write in some Intel(R) Graphics Drivers may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2025-47228 1 Scriptcase 1 Scriptcase 2026-04-15 6.7 Medium
In the Production Environment extension in Netmake ScriptCase through 9.12.006 (23), shell injection in the SSH connection settings allows authenticated attackers to execute system commands via crafted HTTP requests.
CVE-2025-47203 1 Dropbear Ssh Project 1 Dropbear Ssh 2026-04-15 4.5 Medium
dbclient in Dropbear SSH before 2025.88 allows command injection via an untrusted hostname argument, because a shell is used.
CVE-2024-40893 1 Firewalla 1 Box Software 2026-04-15 6.8 Medium
Multiple authenticated operating system (OS) command injection vulnerabilities exist in Firewalla Box Software versions before 1.979. A physically close attacker that is authenticated to the Bluetooth Low-Energy (BTLE) interface can use the network configuration service to inject commands in various configuration parameters including networkConfig.Interface.Phy.Eth0.Extra.PingTestIP, networkConfig.Interface.Phy.Eth0.Extra.DNSTestDomain, and networkConfig.Interface.Phy.Eth0.Gateway6. Additionally, because the configuration can be synced to the Firewalla cloud, the attacker may be able to persist access even after hardware resets and firmware re-flashes.
CVE-2024-40895 2026-04-15 6.4 Medium
FFRI AMC versions 3.4.0 to 3.5.3 and some OEM products that implement/bundle FFRI AMC versions 3.4.0 to 3.5.3 allow a remote unauthenticated attacker to execute arbitrary OS commands when certain conditions are met in an environment where the notification program setting is enabled and the executable file path is set to a batch file (.bat) or command file (.cmd) extension.
CVE-2025-44635 2026-04-15 9.8 Critical
There are multiple unauthorized remote command execution vulnerabilities in the H3C ER2200G2, ERG2-450W, ERG2-1200W, ERG2-1350W, NR1200W series routers before ERG2AW-MNW100-R1117; H3C ER3100G2, ER3200G2, ER3260G2, ER5100G2, ER5200G2, ER6300G2, ER8300G2, ER8300G2-X series routers before ERHMG2-MNW100-R1126; GR3200, GR5200, GR8300 and other series routers before MiniGR1B0V100R018L50; GR-1800AX before MiniGRW1B0V100R009L50; GR-3000AX before SWBRW1A0V100R007L50; and GR-5400AX before SWBRW1B0V100R009L50. Attackers can bypass authentication by including specially crafted text in the request URL or message header, and then inject arbitrary malicious commands into some fields related to ACL access control list and user group functions and execute to obtain the highest ROOT privileges of remote devices, thereby completely taking over the remote target devices.