Search

Search Results (422312 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-118046 2 Rabilal, Wordpress-extensions 2 Js Help Desk – Ai-powered Support & Ticketing System, Js Help Desk 2026-11-10 6.4 Medium
The JS Help Desk – AI-Powered Support & Ticketing System plugin for WordPress is vulnerable to Stored DOM-Based Cross-Site Scripting via the 'jsticket_message' parameter in all versions up to, and including, 5.0.2 due to insufficient input sanitization and output escaping. This makes it possible for authenticated attackers, with subscriber-level access and above, to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page. The payload fires specifically when an administrator or agent opens the affected ticket and the page initializes VenoBox, which reads the browser-decoded data-title attribute and passes it to jQuery .html(), making routine ticket review the trigger condition.
CVE-2026-120540 2 Iubenda, Wordpress-extensions 2 Iubenda, Iubenda 2026-11-10 7.2 High
The iubenda | All-in-one Compliance for GDPR / CCPA Cookie Consent + more plugin for WordPress is vulnerable to Stored Cross-Site Scripting in versions up to, and including, 3.13.6. This is due to the way iubendaParser::parse_comments() re-processes HTML inside IUB-COOKIE-BLOCK markers through the bundled simple_html_dom parser after WordPress has already KSES-filtered the saved comment: simple_html_dom's remove_noise() stores <code> bodies under a deterministic key ('___noise___ 1000') and restore_noise() later substitutes any matching substring back into attribute values WITHOUT re-escaping, allowing a quote-breaking payload stashed in an allowed <code> element to be injected into an allowed <abbr title="___noise___ 1000"> attribute at render time. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page, after an administrator approves the first (otherwise moderated) comment under WordPress's default comment_previously_approved setting.
CVE-2026-12266 1 Zohocorp 1 Ddi Central 2026-11-10 7.6 High
Zoho Corporation ManageEngine DDI Central versions 6200 and below are vulnerable to LDAP bind password exposure through insufficiently protected LDAP settings API.
CVE-2026-12265 1 Zohocorp 1 Ddi Central 2026-11-10 8.8 High
Zoho Corporation ManageEngine DDI Central versions 6200 and below are vulnerable to insufficient access control in HA failover endpoint leading to destructive PostgreSQL database operations.
CVE-2026-12264 1 Zohocorp 1 Ddi Central 2026-11-10 8.8 High
Zoho Corporation ManageEngine DDI Central versions 6200 and below are vulnerable to arbitrary file write via HA Failover Config sync upload leading to code execution as root.
CVE-2026-112137 2026-11-10 5.4 Medium
A vulnerability has been identified in Mendix Studio Pro 11 (All versions >= V11.15.0 < V11.16.0), Mendix Studio Pro 11.12 (All versions >= V11.12.6 < V11.12.7). The affected products MCP Server does not properly validate Content-Type and Origin headers on incoming HTTP requests, leaving it vulnerable to Cross-Site Request Forgery (CSRF). This could allow a malicious web page to trick a user's browser into sending unauthorized requests and executing unintended actions on the local MCP Server.
CVE-2026-112136 2026-11-10 8.8 High
A vulnerability has been identified in Mendix Studio Pro 11 (All versions >= V11.15.0 < V11.16.0), Mendix Studio Pro 11.12 (All versions >= V11.12.6 < V11.12.7). The affected products MCP Server does not properly restrict its HTTP listener to the loopback interface, leaving it potentially exposed to remote systems. This could allow an attacker with network access to interact with the MCP Server remotely.
CVE-2026-109830 2026-11-10 7.3 High
A vulnerability has been identified in meta-iot2050 (All versions >= V01.03.01). Affected devices take parts from a configuration file and execute them unchecked. This could allow an attacker which is able to manipulate the configuration file to make the user execute arbitrary code on the device.
CVE-2026-109097 2026-11-10 8.2 High
A vulnerability has been identified in ROS# (All versions < V2.3.1). Affected systems do not properly escape text of message definition files. This could allow an attacker that is able to pass a crafted message definition file to the user to inject arbitrary code into the generated program.
CVE-2026-64629 1 Siemens 1 Parasolid 2026-11-10 7.8 High
A vulnerability has been identified in Parasolid V38.0 (All versions < V38.0.235), Parasolid V38.1 (All versions < V38.1.230), Simcenter Femap (All versions < V2606.0002). The affected applications contains an out of bounds read vulnerability while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
CVE-2026-59082 2026-11-10 7.8 High
A vulnerability has been identified in SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions), SIMATIC WinCC V8.1 (All versions). Affected devices implicitly execute active content when opening files. This could allow an attacker to make the user execute arbitrary code on the device.
CVE-2026-58115 1 Siemens 1 Simatic Iot2050 2026-11-10 10 Critical
A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions running Example Image versions with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server. This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges.
CVE-2026-58114 2026-11-10 7.5 High
A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions), SIMATIC Information Server 2022 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Process Historian 2020 (All versions), SIMATIC Process Historian 2022 (All versions), SIMATIC WinCC Runtime Professional V17 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions), SIMATIC WinCC Runtime Professional V20 (All versions), SIMATIC WinCC Runtime Professional V21 (All versions), SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions), SIMATIC WinCC V8.1 (All versions). Affected systems do not properly secure their remote user authentication with the deprecated NTLM protocol. This could allow unauthenticated remote attackers, who have achieved a machine in the middle position, to relay NTLM authentication and impersonate a legitimate user. The potential impact depends on the services that are accessible, e.g. a SQL server used by WinCC.
CVE-2025-40759 2026-11-10 7.8 High
A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
CVE-2025-40742 2026-11-10 5.3 Medium
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V11.0), SIPROTEC 5 6MD85 (CP300) (All versions < V11.0), SIPROTEC 5 6MD86 (CP300) (All versions < V11.0), SIPROTEC 5 6MD89 (CP300) (All versions < V11.0), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V11.0), SIPROTEC 5 6MU85 (CP300) (All versions < V11.0), SIPROTEC 5 7KE85 (CP300) (All versions < V11.0), SIPROTEC 5 7SA82 (CP100) (All versions < V8.91), SIPROTEC 5 7SA82 (CP150) (All versions < V11.0), SIPROTEC 5 7SA86 (CP300) (All versions < V11.0), SIPROTEC 5 7SA87 (CP300) (All versions < V11.0), SIPROTEC 5 7SD82 (CP100) (All versions < V8.91), SIPROTEC 5 7SD82 (CP150) (All versions < V11.0), SIPROTEC 5 7SD86 (CP300) (All versions < V11.0), SIPROTEC 5 7SD87 (CP300) (All versions < V11.0), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.91), SIPROTEC 5 7SJ81 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.91), SIPROTEC 5 7SJ82 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ85 (CP300) (All versions < V11.0), SIPROTEC 5 7SJ86 (CP300) (All versions < V11.0), SIPROTEC 5 7SK82 (CP100) (All versions < V8.91), SIPROTEC 5 7SK82 (CP150) (All versions < V11.0), SIPROTEC 5 7SK85 (CP300) (All versions < V11.0), SIPROTEC 5 7SL82 (CP100) (All versions < V8.91), SIPROTEC 5 7SL82 (CP150) (All versions < V11.0), SIPROTEC 5 7SL86 (CP300) (All versions < V11.0), SIPROTEC 5 7SL87 (CP300) (All versions < V11.0), SIPROTEC 5 7SS85 (CP300) (All versions < V11.0), SIPROTEC 5 7ST85 (CP300) (All versions < V11.0), SIPROTEC 5 7ST86 (CP300) (All versions < V11.0), SIPROTEC 5 7SX82 (CP150) (All versions < V11.0), SIPROTEC 5 7SX85 (CP300) (All versions < V11.0), SIPROTEC 5 7SY82 (CP150) (All versions < V11.0), SIPROTEC 5 7UM85 (CP300) (All versions < V11.0), SIPROTEC 5 7UT82 (CP100) (All versions < V8.91), SIPROTEC 5 7UT82 (CP150) (All versions < V11.0), SIPROTEC 5 7UT85 (CP300) (All versions < V11.0), SIPROTEC 5 7UT86 (CP300) (All versions < V11.0), SIPROTEC 5 7UT87 (CP300) (All versions < V11.0), SIPROTEC 5 7VE85 (CP300) (All versions < V11.0), SIPROTEC 5 7VK87 (CP300) (All versions < V11.0), SIPROTEC 5 7VU85 (CP300) (All versions < V11.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V11.0). The affected devices include session identifiers in URL requests for certain functionalities. This could allow an attacker to retrieve sensitive session data from browser history, logs, or other storage mechanisms, potentially leading to unauthorized access.
CVE-2024-54678 1 Siemens 13 Simatic Pcs Neo, Simatic S7-plcsim, Simatic Step 7 and 10 more 2026-11-10 8.2 High
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions < V17 Update 9), SIMOTION SCOUT TIA V5.5 (All versions < V18 Update 6), SIMOTION SCOUT TIA V5.6 (All versions < V19 Update 4), SIMOTION SCOUT TIA V5.7 (All versions < V20 Update 4), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2), TIA Portal Test Suite V20 (All versions < V20 Update 4). Affected products do not properly sanitize Interprocess Communication input received through a Windows Named Pipe accessible to all local users. This could allow an authenticated local attacker to cause a type confusion and execute arbitrary code within the affected application.
CVE-2024-49849 2026-11-10 7.8 High
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions < V17 Update 9), SIMOTION SCOUT TIA V5.5 (All versions < V18 Update 6), SIMOTION SCOUT TIA V5.6 (All versions < V19 Update 4), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions < V18 Update 6), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1). Affected products do not properly sanitize user-controllable input when parsing log files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
CVE-2026-12574 1 Zohocorp 1 Ddi Central 2026-11-10 8.1 High
Zoho Corporation ManageEngine DDI Central versions 6200 and below are vulnerable to Server-side HTML/JavaScript injection in analytics PDF generation leading to local file disclosure.
CVE-2026-125709 1 Redhat 4 Enterprise Linux, Hummingbird, Openshift and 1 more 2026-11-10 4.2 Medium
A flaw was found in libstdc++. When a byte-by-byte write operation fails during file stream processing, the library may still append data into the internal memory buffer. An attacker capable of inducing repeated write failures in an affected service can trigger a buffer overflow, potentially resulting in a Denial of Service (DoS) or memory corruption.
CVE-2026-125707 1 Redhat 2 Enterprise Linux, Rhel Els 2026-11-10 6.1 Medium
A flaw was found in GStreamer's MXF demuxer. When an application processes a crafted MXF file, an off-by-one bounds check can allow a one-byte write past the logical end of a temporal offset array. This may corrupt memory and cause the application to crash. The extent of the impact has not been demonstrated by a runtime test.