| We observed that Intellispace Portal binaries doesn’t have any protection mechanisms to prevent reverse engineering. Specifically, the app’s code is not obfuscated, and no measures are in place to protect against decompilation, disassembly, or debugging. As a result, attackers can reverse-engineer the application to gain insights into its internal workings, which can potentially lead to the discovery of sensitive information, business logic flaws, and other vulnerabilities.
Utilizing this flaw, the attacker was able to identify the Hardcoded credentials from PortalUsersDatabase.dll, which contains .NET remoting definition. Inside the namespace PortalUsersDatabase, the class Users contains the functions CreateAdmin and CreateService that are used to initialize accounts in the Portal service. Both CreateAdmin and CreateService functions contain a hardcoded encrypted password along with its respective salt that are set with the function SetInitialPasswordAndSalt.
This issue affects IntelliSpace Portal: 12 and prior; Advanced Visualization Workspace: 15. |
| A security issue was discovered in the Kubernetes Image Builder where default credentials are enabled during the Windows image build process when using the Nutanix or VMware OVA providers. These credentials, which allow root access, are disabled at the conclusion of the build. Kubernetes clusters are only affected if their nodes use VM images created via the Image Builder project and the vulnerability was exploited during the build process, which requires an attacker to access the build VM and modify the image while the build is in progress. |
| The firmware in KAON CG3000TC and CG3000T routers contains hard-coded credentials in clear text (shared across all routers of this model) that an unauthenticated remote attacker could use to execute commands with root privileges.
This vulnerability has been fixed in firmware version: 1.00.67 for CG3000TC and 1.00.27 for CG3000T. |
| DCIM dcTrack platforms utilize default and hard-coded credentials for access. An attacker could use these credentials to administer the database, escalate privileges on the platform or execute system commands on the host. |
| Hardcoded credentials in gsigel14 ATLAS-EPIC commit f29312c (2025-05-26). |
| Dormakaba provides the software FWServiceTool to update the firmware version of the Access Managers via the network. The firmware in some instances is provided in an encrypted ZIP file. Within this tool, the password used to decrypt the ZIP and extract the firmware is set statically and can be extracted. This password was valid for multiple observed firmware versions. |
| The default password for the extended admin user mode in the application U9ExosAdmin.exe ("Kaba 9300 Administration") is hard-coded in multiple locations as well as documented in the locally stored user documentation. |
| The program libraries (DLL) and binaries used by exos 9300 contain multiple hard-coded secrets. One notable example is the function "EncryptAndDecrypt" in the library Kaba.EXOS.common.dll. This algorithm uses a simple XOR encryption technique combined with a cryptographic key (cryptoKey) to transform each character of the input string. However, it's important to note that this implementation does not provide strong encryption and should not be considered secure for sensitive data. It's more of a custom encryption approach rather than a common algorithm used in cryptographic applications. The key itself is static and based on the founder's name of the company. The functionality is for example used to encrypt the user PINs before storing them in the MSSQL database. |
| An RPC service, which is part of exos 9300, is reachable on port 4000, run by the process FSMobilePhoneInterface.exe. This service is used for interprocess communication between services and the Kaba exos 9300 GUI, containing status information about the Access Managers. Interacting with the service does not require any authentication. Therefore, it is possible to send arbitrary status information about door contacts etc. without prior authentication. |
| Multiple hardcoded credentials have been identified, which are allowed to sign-in to the exos 9300 datapoint server running on port 1004 and 1005. This server is used for relaying status information from and to the Access Managers. This information, among other things, is used to graphically visualize open doors and alerts. However, controlling the Access Managers via this interface is also possible.
To send and receive status information, authentication is necessary. The Kaba exos 9300 application contains hard-coded credentials for four different users, which are allowed to login to the datapoint server and receive as well as send information, including commands to open arbitrary doors. |
| A vulnerability was discovered in the storage policy for certain sets of authentication keys in the HPE Telco Network Function Virtual Orchestrator. Successful Exploitation could lead to unauthorized parties gaining access to sensitive system information. |
| AiKaan Cloud Controller uses a single hardcoded SSH private key and the username `proxyuser` for remote terminal access to all managed IoT/edge devices. When an administrator initiates "Open Remote Terminal" from the AiKaan dashboard, the controller sends this same static private key to the target device. The device then uses it to establish a reverse SSH tunnel to a remote access server, enabling browser-based SSH access for the administrator. Because the same `proxyuser` account and SSH key are reused across all customer environments: - An attacker who obtains the key (e.g., by intercepting it in transit, extracting it from the remote access server, or from a compromised admin account) can impersonate any managed device. - They can establish unauthorized reverse SSH tunnels and interact with devices without the owner's consent. This is a design flaw in the authentication model: compromise of a single key compromises the trust boundary between the controller and devices. |
| An issue in H3C Magic M Device M2V100R006 allows a remote attacker to execute arbitrary code via the default password |
| An issue in H3C Device R365V300R004 allows a remote attacker to execute arbitrary code via the default password. NOTE: the Supplier's position is that their "product lines enforce or clearly prompt users to change any initial credentials upon first use. At most, this would be a case of misconfiguration if an administrator deliberately ignored the prompts, which is outside the scope of CVE definitions." |
| api is a module for FreePBX@, which is an open source GUI that controls and manages Asterisk© (PBX). In versions lower than 15.0.13, 16.0.2 through 16.0.14, 17.0.1 and 17.0.2, there is an identical OAuth private key used across multiple systems that installed the same FreePBX RPM or DEB package. An attacker with access to the shared OAuth private key could forge JWT tokens, bypass authentication, and potentially gain full access to both REST and GraphQL APIs. Systems with the "api" module enabled, configured and previously activated by an administrator for remote inbound connections may be affected. This issue is fixed in versions 15.0.13, 16.0.15 and 17.0.3. |
| CWE-798 Use of Hard-coded Credentials |
| A vulnerability has been discovered in the firmware of Paxton Paxton10 before 4.6 SR6. The firmware file, rootfs.tar.gz, contains hard-coded credentials for the Twilio API. A remote attacker who obtains a copy of the firmware can extract these credentials. This could allow the attacker to gain unauthorized access to the associated Twilio account, leading to information disclosure, potential service disruption, and unauthorized use of the Twilio services. |
| AMSS++ 4.7 contains an authentication bypass vulnerability that allows attackers to access administrative accounts using hardcoded credentials. Attackers can log in with the default admin username and password '1234' to gain unauthorized administrative access to the system. |
| Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to disclose information such as generated power and electricity sold back to the grid stored in the product, tamper with or destroy stored or configured information in the product, or cause a Denial-of-Service (DoS) condition on the product, by using hardcoded user ID and password common to the product series obtained by exploiting CVE-2025-5022. The affected products discontinued in 2015, support ended in 2020. |
| The ArchiverSpaApi ASP.NET application uses a hard-coded JWT signing key. An unauthenticated remote attacker can generate and use a verifiable JWT token to access protected ArchiverSpaApi URL endpoints. |