| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Pass-Back vulnerability in versions prior to 2025.35.000 of Sage 200 Spain. This vulnerability allows an authenticated attacker with administrator privileges to discover stored SMTP credentials. |
| EasyFlow GP developed by Digiwin has an Insufficiently Protected Credentials vulnerability, allowing privileged remote attackers to obtain plaintext credentials of AD and system mail from the system frontend. |
| EasyFlow GP developed by Digiwin has an Insufficiently Protected Credentials vulnerability, allowing privileged remote attackers to obtain plaintext database account credentials from the system frontend. |
| The Ubia camera ecosystem fails to adequately secure API credentials,
potentially enabling an attacker to connect to backend services. The
attacker would then be able to gain unauthorized access to available
cameras, enabling the viewing of live feeds or modification of settings. |
| The standard user uses the run as function to start the MEAC applications with administrative privileges. To ensure that the system can startup on its own, the credentials of the administrator were stored. Consequently, the EPC2 user can execute any command with administrative privileges. This allows a privilege escalation to the administrative level. |
| A vulnerability has been identified in the way that Rancher stores vSphere's CPI (Cloud Provider Interface) and CSI (Container Storage Interface) credentials used to deploy clusters through the vSphere cloud provider. This issue leads to the vSphere CPI and CSI passwords being stored in a plaintext object inside Rancher. This vulnerability is only applicable to users that deploy clusters in vSphere environments. |
| The EWON FLEXY 202 transmits credentials using a weak encoding method base64. An attacker who is present in the network can sniff the traffic and decode the credentials. |
| Password Vulnerability in Safety production process management system v1.0 allows a remote attacker to escalate privileges, execute arbitrary code and obtain sensitive information via the password and account number parameters. |
| A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V05.30). The affected devices contain a secure element which is connected via an unencrypted SPI bus. This could allow an attacker with physical access to the SPI bus to observe the password used for the secure element authentication, and then use the secure element as an oracle to decrypt all encrypted update files. |
| Insufficiently Protected Credentials vulnerability in Baxter Welch Allyn Configuration Tool may allow Remote Services with Stolen Credentials.This issue affects Welch Allyn Configuration Tool: versions 1.9.4.1 and prior. |
| AIPHONE IXG SYSTEM IXG-2C7 firmware Ver.2.03 and earlier and IXG-2C7-L firmware Ver.2.03 and earlier contain an issue with insufficiently protected credentials, which may allow a network-adjacent authenticated attacker to perform unintended operations. |
| Requests is a HTTP library. Due to a URL parsing issue, Requests releases prior to 2.32.4 may leak .netrc credentials to third parties for specific maliciously-crafted URLs. Users should upgrade to version 2.32.4 to receive a fix. For older versions of Requests, use of the .netrc file can be disabled with `trust_env=False` on one's Requests Session. |
| Kieback & Peter's DDC4000 series has an insufficiently protected credentials vulnerability, which may allow an unauthenticated attacker with access to /etc/passwd to read the password hashes of all users on the system. |
| The product transmits or stores authentication credentials, but it uses an insecure method that is susceptible to unauthorized interception and/or retrieval. (CWE-522)
Hitachi Vantara Pentaho Data Integration & Analytics versions before 10.2.0.0 and 9.3.0.8, including 8.3.x, discloses database passwords when saving connections to RedShift.
Products must not disclose sensitive information without cause. Disclosure of sensitive information can lead to further exploitation. |
| apko is an apk-based OCI image builder. apko exposures HTTP basic auth credentials from repository and keyring URLs in log output. This vulnerability is fixed in v0.14.5. |
| Westermo EDW-100 devices through 2024-05-03 allow an unauthenticated user to download a configuration file containing a cleartext password. NOTE: this is a serial-to-Ethernet converter that should not be placed at the edge of the network. |
| ci solution CI-Out-of-Office Manager through 6.0.0.77 uses a Hard-coded Cryptographic Key. |
| HCL DRYiCE Optibot Reset Station is impacted by a missing Strict Transport Security Header. This could allow an attacker to intercept or manipulate data during redirection. |
| Insufficiently protected credentials in GE HealthCare EchoPAC products |
| The /WmAdmin/,/invoke/vm.server/login login page in the Integration Server in Software AG webMethods 10.15.0 before Core_Fix7 allows remote attackers to reach the administration panel and discover hostname and version information by sending an arbitrary username and a blank password to the /WmAdmin/#/login/ URI. |