| Let's Encrypt client and ACME library written in Go (Lego). In versions 4.25.1 and below, the github.com/go-acme/lego/v4/acme/api package (thus the lego library and the lego cli as well) don't enforce HTTPS when talking to CAs as an ACME client. Unlike the http-01 challenge which solves an ACME challenge over unencrypted HTTP, the ACME protocol requires HTTPS when a client communicates with the CA to performs ACME functions. However, the library fails to enforce HTTPS both in the original discover URL (configured by the library user) and in the subsequent addresses returned by the CAs in the directory and order objects. If users input HTTP URLs or CAs misconfigure endpoints, protocol operations occur over HTTP instead of HTTPS. This compromises privacy by exposing request/response details like account and request identifiers to network attackers. This was fixed in version 4.25.2. |
| Cognex In-Sight Explorer and In-Sight Camera Firmware expose
a proprietary protocol on TCP port 1069 to perform management operations
such as modifying system properties. The user management functionality
handles sensitive data such as registered usernames and passwords over
an unencrypted channel, allowing an adjacent attacker to intercept valid
credentials to gain access to the device. |
| Components of the YoSmart YoLink ecosystem through 2025-10-02 leverage unencrypted MQTT to communicate over the internet. An attacker with the ability to monitor network traffic could therefore obtain sensitive information or tamper with the traffic to control affected devices. This affects YoLink Hub 0382, YoLink Mobile Application 1.40.41, and YoLink MQTT Broker. NOTE: The vendor states that the vulnerability described (related to insecure transmission) only impacts the legacy mobile application logic, not the Hub hardware or firmware. The Hub functions solely as a pass-through (transparent gateway) for LoRa wireless data and does not inspect or process the application layer data. |
| An issue in MikroTik RouterOS v.7.14.2 and SwOS v.2.18 exposes the WebFig management interface over cleartext HTTP by default, allowing an on-path attacker to execute injected JavaScript in the administrator’s browser and intercept credentials. |
| EWON Flexy 202 transmits user credentials in clear text with no encryption when a user is added, or user credentials are changed via its webpage. |
| Improper data protection on the ventilator's serial interface could allow an attacker to send and receive messages that result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance. |
| IPMI credentials may be captured in XCC audit log entries when the account username length is 16 characters. |
| An issue was discovered on certain Nuki Home Solutions devices. The HTTP API exposed by a Bridge used an unencrypted channel to provide an administrative interface. A token can be easily eavesdropped by a malicious actor to impersonate a legitimate user and gain access to the full set of API endpoints. This affects Nuki Bridge v1 before 1.22.0 and v2 before 2.13.2. |
| Cleartext Transmission of Sensitive Information vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU module allows a remote unauthenticated attacker to obtain credential information by intercepting SLMP communication messages, and read or write the device values of the product and stop the operations of programs by using the obtained credential information. |
| The StrongDM Client insufficiently protected a pre-authentication token. Attackers could exploit this to intercept and reuse the token, potentially redeeming valid authentication credentials through a race condition. |
| This vulnerability exists in Digisol DG-GR6821AC Router due to cleartext transmission of credentials in its web management interface. A remote attacker could exploit this vulnerability by intercepting the network traffic and capturing cleartext credentials.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted device. |
| Aikaan IoT management platform v3.25.0325-5-g2e9c59796 sends a newly generated password to users in plaintext via email and also includes the same password as a query parameter in the account activation URL (e.g., https://domain.com/activate=xyz). This practice can result in password exposure via browser history, proxy logs, referrer headers, and email caching. The vulnerability impacts user credential confidentiality during initial onboarding. |
| Kaleris NAVIS N4 ULC (Ultra Light Client) communicates insecurely using zlib-compressed data over HTTP. An attacker capable of observing network traffic between Ultra Light Clients and N4 servers can extract sensitive information, including plaintext credentials. |
| Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.
The device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.
This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49. |
| This vulnerability exists in the Meon KYC solutions due to transmission of sensitive data in plain text within the response payloads of certain API endpoints. An authenticated remote attacker could exploit this vulnerability by intercepting API response that contains unencrypted sensitive information belonging to other users.
Successful exploitation of this vulnerability could allow remote attacker to impersonate the target user and gain unauthorized access to the user account. |
| A cleartext transmission of sensitive information vulnerability in the affected products allows an unauthorized remote attacker to gain login credentials and access the Web-UI. |
| Bosscomm IF740 Firmware versions:11001.7078 & v11001.0000 and System versions: 6.25 & 6.00 were discovered to send communications to the update API in plaintext, allowing attackers to access sensitive information via a man-in-the-middle attack. |
| Lack of encryption in transit for cloud infrastructure facilitating potential for sensitive data manipulation or exposure. |
| All WorkExaminer Professional traffic between monitoring client, console and server is transmitted as plain text. This allows an attacker with access to the network to read the transmitted sensitive data. An attacker can also freely modify the data on the wire. The monitoring clients transmit their data to the server using the unencrypted FTP. Clients connect to the FTP server on port 12304 and transmit the data unencrypted. In addition, all traffic between the console client and the server at port 12306 is unencrypted. |
| CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists that could result in the exposure
of data when network traffic is being sniffed by an attacker. |