| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Missing authentication for critical function vulnerability exists in ID Link Manager and FUJITSU Software TIME CREATOR. If this vulnerability is exploited, sensitive information may be obtained and/or the information stored in the database may be altered by a remote authenticated attacker. |
| Authorization bypass vulnerability in Hitachi Infrastructure Analytics Advisor (Data Center Analytics component) and Hitachi Ops Center Analyzer (Hitachi Ops Center Analyzer detail view component).This issue affects Hitachi Infrastructure Analytics Advisor:; Hitachi Ops Center Analyzer: from 10.0.0-00 before 11.0.5-00. |
| When configuring Arc (e.g. during the first setup), a local web interface is provided to ease the configuration process. Such web interface lacks authentication and may thus be abused by a local attacker or malware running on the machine itself.
A malicious local user or process, during a window of opportunity when the local web interface is active, may be able to extract sensitive information or change Arc's configuration. This could also lead to arbitrary code execution if a malicious update package is installed. |
| WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) is vulnerable to Broken Access Control in initial configuration wizard.cgi endpoint. Malicious attacker can change admin panel password without authorization. The vulnerability can also be exploited after the initial configuration has been set.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| In WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) due to lack of authentication in the configuration change module in the adm.cgi endpoint, the unauthenticated attacker can execute commands including backup creation, device restart and resetting the device to factory settings.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| FLIR thermal traffic cameras contain an unauthenticated vulnerability that allows remote attackers to access live video streams without credentials. Attackers can directly retrieve video streams by accessing specific endpoints like /live.mjpeg, /snapshot.jpg, and RTSP streaming URLs without authentication. |
| FLIR thermal traffic cameras contain an unauthenticated device manipulation vulnerability in their WebSocket implementation that allows attackers to bypass authentication and authorization controls. Attackers can directly modify device configurations, access system information, and potentially initiate denial of service by sending crafted WebSocket messages without authentication. |
| FLIR Brickstream 3D+ 2.1.742.1842 contains an unauthenticated vulnerability in the ExportConfig REST API that allows attackers to download sensitive configuration files. Attackers can exploit the getConfigExportFile.cgi endpoint to retrieve system configurations, potentially enabling authentication bypass and privilege escalation. |
| FLIR Brickstream 3D+ 2.1.742.1842 contains an unauthenticated vulnerability that allows remote attackers to access live video streams without credentials. Attackers can retrieve video stream images by directly accessing multiple image endpoints like middleImage.jpg, rightimage.jpg, and leftimage.jpg. |
| Akka.NET is a .NET port of the Akka project from the Scala / Java community. In all versions of Akka.Remote from v1.2.0 to v1.5.51, TLS could be enabled via our `akka.remote.dot-netty.tcp` transport and this would correctly enforce private key validation on the server-side of inbound connections. Akka.Remote, however, never asked the outbound-connecting client to present ITS certificate - therefore it's possible for untrusted parties to connect to a private key'd Akka.NET cluster and begin communicating with it without any certificate. The issue here is that for certificate-based authentication to work properly, ensuring that all members of the Akka.Remote network are secured with the same private key, Akka.Remote needed to implement mutual TLS. This was not the case before Akka.NET v1.5.52. Those who run Akka.NET inside a private network that they fully control or who were never using TLS in the first place are now affected by the bug. However, those who use TLS to secure their networks must upgrade to Akka.NET V1.5.52 or later. One patch forces "fail fast" semantics if TLS is enabled but the private key is missing or invalid. Previous versions would only check that once connection attempts occurred. The second patch, a critical fix, enforces mutual TLS (mTLS) by default, so both parties must be keyed using the same certificate. As a workaround, avoid exposing the application publicly to avoid the vulnerability having a practical impact on one's application. However, upgrading to version 1.5.52 is still recommended by the maintainers. |
| Synaccess netBooter NP-02x/NP-08x 6.8 contains an authentication bypass vulnerability in the webNewAcct.cgi script that allows unauthenticated attackers to create admin user accounts. Attackers can exploit the missing control check by sending crafted POST requests to create administrative accounts and gain unauthorized control over power supply management. |
| Authentication Bypass
vulnerability in Hitachi Ops Center Analyzer on Linux, 64 bit (Hitachi Ops Center Analyzer detail view component), Hitachi Infrastructure Analytics Advisor on Linux, 64 bit (Hitachi Data Center Analytics
component
).This issue affects Hitachi Ops Center Analyzer: from 10.0.0-00 before 11.0.3-00; Hitachi Infrastructure Analytics Advisor: from 2.1.0-00 through 4.4.0-00. |
| Karapace is an open-source implementation of Kafka REST and Schema Registry. Versions 5.0.0 and 5.0.1 contain an authentication bypass vulnerability when configured to use OAuth 2.0 Bearer Token authentication. If a request is sent without an Authorization header, the token validation logic is skipped entirely, allowing an unauthenticated user to read and write to Schema Registry endpoints that should otherwise be protected. This effectively renders the OAuth authentication mechanism ineffective. This issue is fixed in version 5.0.2. |
| Unitree Go2, G1, H1, and B2 devices through 2025-09-20 accept any handshake secret with the unitree substring. |
| Certain modes of routers from Billion Electric have a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly access the specific functionality to obtain partial device information, modify the WiFi SSID, and restart the device. |
| A vulnerability classified as problematic was found in Lucky LM-520-SC, LM-520-FSC and LM-520-FSC-SAM up to 20250321. Affected by this vulnerability is an unknown functionality. The manipulation leads to missing authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| General Industrial Controls Lynx+ Gateway
is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device. |
| The devices allow access to an unprotected endpoint that allows MPFS
file system binary image upload without authentication. The MPFS2 file
system module provides a light-weight read-only file system that can be
stored in external EEPROM, external serial flash, or internal flash
program memory. This file system serves as the basis for the HTTP2 web
server module, but is also used by the SNMP module and is available to
other applications that require basic read-only storage capabilities.
This can be exploited to overwrite the flash program memory that holds
the web server's main interfaces and execute arbitrary code. |
| An unauthenticated remote attacker may use the devices traffic capture without authentication to grab plaintext administrative credentials. |
| Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) "Automatic log in" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in. |